Схема подключения подстанции коробчатого типа
Box-Type Substation Wiring Scheme A box-type substation, also known as a compact or prefabricated substation, is an integrated power distribution unit that combines high-voltage switchgear, transformers, and low-voltage distribution equipment in a single enclosure. The wiring scheme of such a substation is designed for efficiency, safety, and ease of maintenance. Below is a detailed description of its typical wiring configuration. 1. High-Voltage (HV) Section The HV section receives power from the grid or a primary distribution network, typically at voltages ranging from 10kV to 35kV. The incoming HV cable connects to a ring main unit (RMU) or load-break switch, which provides protection and isolation. Circuit breakers or fused switches are installed to safeguard against overloads and short circuits. Surge arresters are also integrated to protect against lightning strikes and voltage spikes. 2. Transformer Section The HV power is stepped down to a lower voltage (e.g., 400V or 230V) via an oil-immersed or dry-type transformer. The transformer is selected based on load requirements and environmental conditions. The wiring between the HV and transformer includes insulated busbars or cables, ensuring minimal energy loss and heat dissipation. 3. Low-Voltage (LV) Section The LV section distributes power to end-users through circuit breakers, contactors, and distribution panels. The wiring scheme here includes: - Main LV Circuit Breaker: Protects the system from overloads and faults. - Busbars: Distribute power to multiple outgoing feeders. - Metering and Protection Devices: Include energy meters, relays, and earth leakage detectors for monitoring and safety. - Capacitor Banks (Optional): Used for power factor correction to improve efficiency. 4. Earthing and Safety Measures A proper earthing system is critical to prevent electric shocks and equipment damage. All metallic enclosures, transformer neutrals, and surge arresters are connected to an earth grid. Additionally, interlocks and mechanical barriers prevent accidental contact with live parts. 5. Control and Monitoring Wiring Modern box-type substations incorporate automation via PLCs or SCADA systems for remote monitoring. Control wiring connects sensors, relays, and communication modules to enable real-time data collection and fault detection. Conclusion The wiring scheme of a box-type substation ensures reliable power distribution while maintaining compactness and safety. Proper design considerations, such as load balancing, insulation, and protection mechanisms, contribute to its operational efficiency. Modular construction allows for easy expansion, making it suitable for urban, industrial, and rural applications. This structured approach ensures that the substation operates efficiently while complying with electrical safety standards.
продукт
классификация:
Подстанции коробчатого типа
Нет результатов поиска!
новости
классификация:
Нет результатов поиска!
случай
классификация:
Нет результатов поиска!
видео
классификация:
Нет результатов поиска!
скачать
классификация:
Нет результатов поиска!
вербовка
классификация:
Нет результатов поиска!
Рекомендуемые продукты
Нет результатов поиска!

Тел:+8618084093399










телефон